Magnum Light Towers

Magnum light towers are built and designed for the most extreme environments, from deserts to the frozen tundra. The light tower offers complete flexibility with 360 degree rotation. The four 1,000 watt metal halide lights will fully illuminate up to seven acres.

Our unparalleled customer service/technical support teams and heavy-duty equipment is what gives our customers the ultimate “return on investment.”

MLT3060 Light TowerShowImage

6 kW Mobile Lighting in a Narrow-Bodied Package

Engine

Make/Brand Mitsubishi
Model L3E-W461ML
Aspiration Natural
Type Diesel, liquid cooled, 4-stroke
Power – Prime hp (kW) 10.5 (7.8)
Power – Standby hp (kW) 12.2 (9.1)
Operating Speed rpm 1800
Displacement cubic in (L) 57.97 (0.95)
Cylinders 3
Fuel Consumption – Prime gph (Lph) 0.47 (1.78)

Generator Set (Engine/Gen)

Output – Standby kW (kVA) 6.0 (6.0)
Output Voltage V 120/240
Output Amperes 120V (240V) 50 (25)
Frequency Hz 60
Power Factor 1.0 (1 Phase)

Lighting

Lighting Type Metal halide
Ballast Type Coil & core
Lumens 440,000
Coverage acres (sq. meters) 5 – 7 (20,234 – 28,328)

Electrical Distribution

Circuit Breaker Size 30
Voltage Selection N/A
Voltage Regulation Capacitor +/-6%
AC Voltage – 1 Phase 120, 240
Battery Voltage (qty per unit) 12V (1)
Battery Rating 440 CCA
120V-20 amp GFCI Duplex – qty 1
240V-30 amp Twist Lock – qty 1
240V-50 amp Twist Lock – qty N/A

 

MLT4060 Light Tower676584_0ae1b05c500a356628dedccfbc75f6b0

Highly Mobile Lighting

Engine

Make/Brand Mitsubishi
Model L3E-W461ML
Aspiration Natural
Type Diesel, liquid cooled, 4-stroke
Power – Prime hp (kW) 10.5 (7.8)
Power – Standby hp (kW) 12.2 (9.1)
Operating Speed rpm 1800
Displacement cubic in (L) 57.97 (0.95)
Cylinders 3
Fuel Consumption – Prime gph (Lph) 0.47 (1.78)

Generator Set (Engine/Gen)

Output – Standby kW (kVA) 6.0 (6.0)
Output Voltage V 120/240
Output Amperes 120V (240V) 50 (25)
Frequency Hz 60
Power Factor 1.0 (1 Phase)

Lighting

Lighting Type Metal halide
Ballast Type Coil & core
Lumens 440,000
Coverage acres (sq. meters) 5 – 7 (20,234 – 28,328)

Capacities

Fuel Tank gal (L) 30 (114)
Coolant (incl. engine) qt (L) 4.5 (4.3)
Oil (incl. filter) qt (L) 3.8 (3.6)
Maximum Run Time hrs 64

Electrical Distribution

Circuit Breaker Size 30
Voltage Selection N/A
Voltage Regulation Capacitor +/-6%
AC Voltage – 1 Phase 120, 240
Battery Voltage (qty per unit) 12V (1)
Battery Rating 440 CCA
120V-20 amp GFCI Duplex – qty 1
240V-30 amp Twist Lock – qty 1
240V-50 amp Twist Lock – qty N/A

 

MLT4080 Light Towerserie-4000-mlt4060-4080

Mobile Lighting with 8 kW Power

Engine

Make/Brand Mitsubishi
Model L3E-W461ML
Aspiration Natural
Type Diesel, liquid cooled, 4-stroke
Power – Prime hp (kW) 10.5 (7.8)
Power – Standby hp (kW) 12.2 (9.1)
Operating Speed rpm 1800
Displacement cubic in (L) 57.97 (0.95)
Cylinders 3
Fuel Consumption – Prime gph (Lph) 0.63 (2.38)

Generator Set (Engine/Gen)

Output – Standby kW (kVA) 7.3 (7.3) – Mitsubishi
8.0 (8.0) – Kubota
Output Voltage V 120/240
Output Amperes 120V (240V) 61 (30)
Frequency Hz 60
Power Factor 1.0 (1 Phase)

Lighting

Lighting Type Metal halide
Ballast Type Coil & core
Lumens 440,000
Coverage acres (sq. meters) 5 – 7 (20,234 – 28,328)

Capacities

Fuel Tank gal (L) 30 (114)
Coolant (incl. engine) qt (L) 4.5 (4.3)
Oil (incl. filter) qt (L) 3.8 (3.6)
Maximum Run Time hrs 48

Electrical Distribution

Circuit Breaker Size 40
Voltage Selection N/A
Voltage Regulation Capacitor +/-6%
AC Voltage – 1 Phase 120, 240
Battery Voltage (qty per unit) 12V (1)
Battery Rating 440 CCA
120V-20 amp GFCI Duplex – qty 2
240V-30 amp Twist Lock – qty 1
240V-50 amp Twist Lock – qty N/A